GASKET : PTFE/NBR
BUSH : BRASS
BODY : BRASS
CORE: STAINLESS
TEMPERATURE : -10 / +150 °C
Full Bore General Purpose Normally Open Solenoid Valve are two or three way valves that operate with AC and DC electrical energy and provide control of various fluids (air, gas, fuel, steam, water, etc.). It consists of body, sleeve, coil, diaphragm and core. Solenoid valves are manufactured in two types as normally closed (to open the closed valve when the coil receives energy) and normally open (to close the open valve when it receives energy from the coil).
THINGS TO PAY ATTENTION:
-The coil should be selected in accordance with the operating voltage (AC-DC). Protection and insulation according to the application area
should be provided. (Electricity turns on when air comes in, and turns off again when you cut off the electricity.)
-Min . and max. in the line or system you will use. pressure values are very important in the selection of the valve.
-The quality and temperature of the fluid is a direct factor in the selection of the valve.
-The direction of the fluid and the arrow mark on the body are in the same direction and attention should be paid to assembly.
- Since the solenoid valve does not function as a check valve, the fluid flows back in reverse pressures. In these cases, the solenoid valve
then installing a check valve is correct in terms of connection.
-The line to which the valve is attached must be free of impurities.